A 3 kW roof, a 10 kWh battery and a heat pump are three different bets. The first is settled by the progressive tariff and net metering, the second by the gap between off-peak and peak, the third by COP against the gas meter. Four calculators put the same numbers side by side, then carry them through twenty years of cash flow. Inputs stay in your browser and ride only after the # in the address.
Tier 120.0 / 214.6 / 307.3
Summer 300 / 450 kWh
Net metering 1:1
Off-peak 116.0
Basis 2026.11.28
Solar self-consumption and net metering
region · capacity · usage
Roof
kW
%
%
Use
kWh
%
Settlement
Annual generation
—
Self-consumed
—
Surplus
—
Self-consumption ratio
—
Bill before, per year
—
Bill after, per year
—
Annual saving
—
20-year saving (degradation, 3% price rise)
—
Year-end unused credit
—
Month by month kWh · KRW
Month
Generation
Use
Self-use
Surplus
Bill before
Bill after
Saving
The bill follows the KEPCO residential tariff: basic fee from the tier reached, energy at 120.0 / 214.6 / 307.3 KRW per kWh for low voltage, climate 9.0 and fuel adjustment 5.0 KRW added per kWh, then 10% VAT and 2.7% of the power-industry fund. Under net metering only the energy charge is netted, so the basic fee, the two per-kWh levies and VAT stay as they were — a deliberately conservative reading of the rule.
Battery arbitrage on time-of-use rates
capacity · efficiency · price gap
Battery
kWh
%
%
yrs
Assumptions
Rates
KRW
KRW
Cost
KRW
KRW
Saving per year
—
Payback
—
Discharge per cycle
—
Charge per cycle
—
Saving per day
—
Battery life
—
Net cost after subsidy
—
Ten-year saving
—
Ten-year return on cost
—
Each cycle discharges capacity × depth of discharge and needs that much divided by round-trip efficiency to refill. The saving is discharge × peak price minus charge × off-peak price, times cycles and operating days. Rates default to KEPCO industrial (Eul) high-voltage A option II for summer 2026: off-peak 116.0, peak 229.0 KRW. Mainland homes on the residential tariff have no time-of-use option; Jeju does, and commercial premises do.
Heat pump against gas or kerosene
COP · heat load · fuel price
Heating
kWh
%
%
Electricity
KRW
KRW
Investment
KRW
KRW
KRW
Annual saving
—
Heat pump, per year
—
Boiler, per year
—
Saving as a share
—
CO2 before
—
CO2 after
—
CO2 avoided per year
—
Payback
—
20-year saving (degradation, 3% price rise)
—
The heat pump delivers the annual heat load divided by its COP in electricity. The gas boiler burns heat load × 3.6 ÷ efficiency in MJ at 22.5268 KRW per MJ (Seoul, 1 November 2026) plus the 1,250 KRW monthly basic fee and 10% VAT; kerosene burns heat ÷ 36.6 MJ per litre ÷ efficiency at 1,570.33 KRW per litre. Emissions use 0.4173 kg CO2e per kWh of grid power, 2.16 kg per Nm3 of city gas and 2.46 kg per litre of kerosene.
Twenty-year NPV, IRR and payback
capex · subsidy · scenarios
Investment
KRW
KRW
KRW
Assumptions
%
%
%
Replacement
yrs
KRW
yrs
KRW
NPV
—
IRR
—
Simple payback
—
Discounted payback
—
Total net cash, 20 years
—
0% rise
—
Base
—
+5% a year
—
Cumulative cash flow Cumulative net cash by year; the horizontal line is break-even.
Year
Net cash
Cumulative
Discounted
The file carries one annual inspection per year and any replacement you set, as all-day events.
Estimates only. Installation quotes, the actual meter, roof conditions and the rules in force at the time decide the real figure.
How the numbers are built
The order of the arithmetic
01
Set the roof
Region, capacity, orientation, shading and degradation decide how many kilowatt-hours arrive each month.
02
Price them
The tariff ladder turns those kilowatt-hours into a bill before and after, month by month.
03
Add the devices
A battery moves energy from the cheap hours to the expensive ones; a heat pump moves heat instead of burning fuel.
04
Read twenty years
Subsidy, maintenance, replacement and the discount rate produce NPV, IRR and a calendar you can export.
Every calculator runs on the same four inputs: the tariff ladder, the generation profile, the efficiency of the device and the price of the fuel it replaces. The twenty-year table then applies degradation, maintenance, replacement and the discount rate to the year-one saving.
Four steps from the roof to the spreadsheet
The same cash flow, read four ways.
One kWh is worth three prices
At home the same kilowatt-hour costs 120.0, 214.6 or 307.3 KRW depending on how much the household has already used that month, and the basic fee jumps from 1,600 to 7,300 KRW the moment 400 kWh is crossed. A rooftop unit therefore earns most where the tier is highest.
Summer widens the ladder
From 1 July to 31 August the first tier runs to 300 kWh and the second to 450. The rates do not change; the same 450 kWh falls from 108,050 to 85,740 KRW, which is exactly the window a summer-heavy household should model.
Net metering is not a feed-in tariff
Surplus is netted against the energy charge at the same price, month by month. The basic fee, the climate and fuel levies and VAT stay on the pre-netting volume, so the saving is smaller than a naive multiply suggests. Unused credit expires for systems up to 10 kW.
A battery sells the gap, not the energy
Charging at 116.0 and discharging at 229.0 earns 113 KRW per kWh before efficiency; at 90% round-trip the real spread is about 100 KRW. Ten kWh of usable capacity on one cycle a day is roughly 365,000 KRW a year, which is the number to hold against the installed cost.
The heat pump is a COP bet
One kilowatt-hour at 130 KRW and a COP of 3.2 buys 3.2 kWh of heat, about 40.6 KRW each. City gas at 22.5268 KRW per MJ and 92% efficiency costs about 96.9 KRW per kWh of heat, because a kilowatt-hour is 3.6 MJ. The heat pump wins by more than twice until electricity reaches the third tier at 307.3 KRW, where the two meet.
Twenty years is where the arguments settle
Degradation at 0.5% a year, an inverter near year twelve and a discount rate of 4.5% turn a strong year-one saving into a modest but real NPV. The table shows every year so the payback and the IRR can be read against the same cash flow.
736.2 KRW above 1,000 kWh in July–August and December–February
Basic supply terms
Per-kWh levies
Climate 9.0 + fuel adjustment 5.0 KRW
KEPCO, Q4 2026
Tax and fund
VAT 10% and 2.7% power-industry fund
Since 1 July 2025
Net metering
Energy charge netted 1:1; basic fee and VAT unchanged
Small-scale trading rules art. 18
Surplus
Carried monthly; annual SMP cash only above 10 kW
KEPCO netting practice
Rooftop subsidy
550,000 KRW per kW up to 3 kW (low-carbon modules)
KEPCO/KEA 2026 programme
Heat pump support
70% of cost, up to 9.8m KRW
Heating electrification 2026
City gas
22.5268 KRW per MJ + 1,250 KRW a month
Seoul City Gas, 1 Nov 2026
Kerosene
1,570.33 KRW per litre
Opinet weekly average, Nov 2026
Nothing leaves the page
No account, no upload, no analytics and no server calculation. The only stored value is your theme, and the only external script is the ad loader, which refuses to run outside opyeb.com.
Yes. The basic fee follows the tier the month's total use reaches, including the wider summer bands, so crossing 400 kWh in March costs 5,700 KRW more before any energy is counted.
Why is my saving smaller than generation × my rate?
Because only the energy charge is netted, and because part of the generation replaces cheap first-tier kilowatt-hours rather than expensive third-tier ones. The month-by-month table shows exactly where each kilowatt-hour lands.
Can I be paid for surplus?
Up to 10 kW the credit is carried forward and expires; above 10 kW you may take an annual cash settlement at the SMP average, which was around 104 KRW per kWh in September 2026 — well below the retail energy rate.
Is a home battery profitable in Korea?
On the residential tariff alone, rarely: there is no time-of-use option on the mainland, so a battery earns by raising self-consumption. On a commercial time-of-use meter the off-peak to peak gap of 113 KRW per kWh is where the money is.
Does the heat pump always beat gas?
On the price of heat, usually: 130 KRW per kWh at COP 3.2 is 40.6 KRW per kWh of heat against 96.9 KRW for condensing gas. The gap closes at the third-tier electricity price of 307.3 KRW, or when a separate meter adds a basic fee (about 6,160 KRW per kW a month), which is why the tariff choice matters as much as the COP.
What discount rate should I use?
A rate near the interest you would otherwise earn or pay: 4.5% is a common planning figure. A higher rate shortens the apparent value of distant savings and lengthens the discounted payback.
Guides
Thirty guides in Korean and thirty in English explain each number.