opyeb SolarROI

Korea 2026 · solar · battery · heating

What a roof
actually returns.

A 3 kW roof, a 10 kWh battery and a heat pump are three different bets. The first is settled by the progressive tariff and net metering, the second by the gap between off-peak and peak, the third by COP against the gas meter. Four calculators put the same numbers side by side, then carry them through twenty years of cash flow. Inputs stay in your browser and ride only after the # in the address.

Solar self-consumption and net metering

region · capacity · usage

Roof

kW
%
%

Use

kWh
%

Settlement

Annual generation
—
Self-consumed
—
Surplus
—
Self-consumption ratio
—
Bill before, per year
—
Bill after, per year
—
Annual saving
—
20-year saving (degradation, 3% price rise)
—
Year-end unused credit
—

Month by month kWh · KRW

MonthGenerationUseSelf-useSurplusBill beforeBill afterSaving

The bill follows the KEPCO residential tariff: basic fee from the tier reached, energy at 120.0 / 214.6 / 307.3 KRW per kWh for low voltage, climate 9.0 and fuel adjustment 5.0 KRW added per kWh, then 10% VAT and 2.7% of the power-industry fund. Under net metering only the energy charge is netted, so the basic fee, the two per-kWh levies and VAT stay as they were — a deliberately conservative reading of the rule.

Estimates only. Installation quotes, the actual meter, roof conditions and the rules in force at the time decide the real figure.

How the numbers are built

The order of the arithmetic
  1. 01

    Set the roof

    Region, capacity, orientation, shading and degradation decide how many kilowatt-hours arrive each month.

  2. 02

    Price them

    The tariff ladder turns those kilowatt-hours into a bill before and after, month by month.

  3. 03

    Add the devices

    A battery moves energy from the cheap hours to the expensive ones; a heat pump moves heat instead of burning fuel.

  4. 04

    Read twenty years

    Subsidy, maintenance, replacement and the discount rate produce NPV, IRR and a calendar you can export.

Every calculator runs on the same four inputs: the tariff ladder, the generation profile, the efficiency of the device and the price of the fuel it replaces. The twenty-year table then applies degradation, maintenance, replacement and the discount rate to the year-one saving.

Four steps from the roof to the spreadsheet

The same cash flow, read four ways.

One kWh is worth three prices

At home the same kilowatt-hour costs 120.0, 214.6 or 307.3 KRW depending on how much the household has already used that month, and the basic fee jumps from 1,600 to 7,300 KRW the moment 400 kWh is crossed. A rooftop unit therefore earns most where the tier is highest.

Summer widens the ladder

From 1 July to 31 August the first tier runs to 300 kWh and the second to 450. The rates do not change; the same 450 kWh falls from 108,050 to 85,740 KRW, which is exactly the window a summer-heavy household should model.

Net metering is not a feed-in tariff

Surplus is netted against the energy charge at the same price, month by month. The basic fee, the climate and fuel levies and VAT stay on the pre-netting volume, so the saving is smaller than a naive multiply suggests. Unused credit expires for systems up to 10 kW.

A battery sells the gap, not the energy

Charging at 116.0 and discharging at 229.0 earns 113 KRW per kWh before efficiency; at 90% round-trip the real spread is about 100 KRW. Ten kWh of usable capacity on one cycle a day is roughly 365,000 KRW a year, which is the number to hold against the installed cost.

The heat pump is a COP bet

One kilowatt-hour at 130 KRW and a COP of 3.2 buys 3.2 kWh of heat, about 40.6 KRW each. City gas at 22.5268 KRW per MJ and 92% efficiency costs about 96.9 KRW per kWh of heat, because a kilowatt-hour is 3.6 MJ. The heat pump wins by more than twice until electricity reaches the third tier at 307.3 KRW, where the two meet.

Twenty years is where the arguments settle

Degradation at 0.5% a year, an inverter near year twelve and a discount rate of 4.5% turn a strong year-one saving into a modest but real NPV. The table shows every year so the payback and the IRR can be read against the same cash flow.

A month of the residential ladder

Monthly useLow voltage, other monthsLow voltage, July–August
200 kWh31,220 KRW31,220 KRW
300 kWh57,760 KRW46,320 KRW
400 kWh83,530 KRW72,860 KRW
450 kWh108,050 KRW85,740 KRW
500 kWh126,160 KRW110,280 KRW
600 kWh162,370 KRW146,480 KRW

Battery arbitrage at the 2026 industrial rates

SeasonOff-peakMid-peakPeak
Summer (Jun–Aug)116.0163.8229.0
Spring and autumn116.0133.4150.9
Winter (Nov–Feb)123.0164.0204.6

Basis · 2026

Rule2026 valueWhere it comes from
Residential low voltageBasic 910 / 1,600 / 7,300 KRW; energy 120.0 / 214.6 / 307.3KEPCO tariff, 9 Nov 2023
Residential high voltageBasic 730 / 1,260 / 6,060; energy 105.0 / 174.0 / 242.3KEPCO tariff
Summer tiers300 kWh and 450 kWh from 1 July to 31 AugustBasic supply terms, table 1
Super-user rate736.2 KRW above 1,000 kWh in July–August and December–FebruaryBasic supply terms
Per-kWh leviesClimate 9.0 + fuel adjustment 5.0 KRWKEPCO, Q4 2026
Tax and fundVAT 10% and 2.7% power-industry fundSince 1 July 2025
Net meteringEnergy charge netted 1:1; basic fee and VAT unchangedSmall-scale trading rules art. 18
SurplusCarried monthly; annual SMP cash only above 10 kWKEPCO netting practice
Rooftop subsidy550,000 KRW per kW up to 3 kW (low-carbon modules)KEPCO/KEA 2026 programme
Heat pump support70% of cost, up to 9.8m KRWHeating electrification 2026
City gas22.5268 KRW per MJ + 1,250 KRW a monthSeoul City Gas, 1 Nov 2026
Kerosene1,570.33 KRW per litreOpinet weekly average, Nov 2026

Nothing leaves the page

No account, no upload, no analytics and no server calculation. The only stored value is your theme, and the only external script is the ad loader, which refuses to run outside opyeb.com.

Read the privacy note →

Questions

Does the calculator include the basic fee?

Yes. The basic fee follows the tier the month's total use reaches, including the wider summer bands, so crossing 400 kWh in March costs 5,700 KRW more before any energy is counted.

Why is my saving smaller than generation × my rate?

Because only the energy charge is netted, and because part of the generation replaces cheap first-tier kilowatt-hours rather than expensive third-tier ones. The month-by-month table shows exactly where each kilowatt-hour lands.

Can I be paid for surplus?

Up to 10 kW the credit is carried forward and expires; above 10 kW you may take an annual cash settlement at the SMP average, which was around 104 KRW per kWh in September 2026 — well below the retail energy rate.

Is a home battery profitable in Korea?

On the residential tariff alone, rarely: there is no time-of-use option on the mainland, so a battery earns by raising self-consumption. On a commercial time-of-use meter the off-peak to peak gap of 113 KRW per kWh is where the money is.

Does the heat pump always beat gas?

On the price of heat, usually: 130 KRW per kWh at COP 3.2 is 40.6 KRW per kWh of heat against 96.9 KRW for condensing gas. The gap closes at the third-tier electricity price of 307.3 KRW, or when a separate meter adds a basic fee (about 6,160 KRW per kW a month), which is why the tariff choice matters as much as the COP.

What discount rate should I use?

A rate near the interest you would otherwise earn or pay: 4.5% is a common planning figure. A higher rate shortens the apparent value of distant savings and lengthens the discounted payback.

Enquiries go through the single OPYEB contact form (https://opyeb.com/contact/). The site asks for no name, phone number, address or account.