ESS arbitrage: charge off-peak, discharge at peak
A battery does not make electricity; it moves it in time. Charging when power is cheap and discharging when it is expensive turns the price gap into revenue. At the 2026 industrial rates, off-peak is 116.0 KRW and the summer peak 229.0, a gap of 113 KRW per kWh.
One cycle, step by step
Take 10 kWh of capacity, 90% depth of discharge and 90% round-trip efficiency. Each cycle discharges 9 kWh and needs 9 ÷ 0.9 = 10 kWh to refill. Charging costs 10 × 116 = 1,160 KRW and the discharge is worth 9 × 229 = 2,061 KRW. The day earns 901 KRW, or 328,865 KRW over 365 days.
Add the seasons and the picture changes. A winter peak of 204.6 makes the discharge worth 1,841 KRW, while an off-peak of 123.0 raises the charge to 1,230, leaving 611 KRW a day. A single representative rate overstates the year, so test the conservative season too.
| Season | Off-peak | Peak | Gap per kWh | 10 kWh per day |
|---|---|---|---|---|
| Summer | 116.0 | 229.0 | 113.0 | 901 KRW |
| Spring and autumn | 116.0 | 150.9 | 34.9 | 208 KRW |
| Winter | 123.0 | 204.6 | 81.6 | 611 KRW |
The spring and autumn gap is strikingly small. The April 2026 reform cut the peak rate and raised the off-peak rate, compressing the spread. A spring day earns 208 KRW, a quarter of summer. Using only the summer rate multiplies the annual return by roughly two.
Charging from solar surplus
If the battery charges from surplus solar rather than the grid, the charge costs nothing and the day earns discharge × peak, 9 × 229 = 2,061 KRW. The same battery earns more than twice as much. The catch is that surplus is only available when the array is producing, so a battery larger than the daily surplus sits empty.
A 3 kW array makes 10–15 kWh a day and leaves 5–10 kWh of surplus after self-consumption. Filling a 10 kWh battery needs a clear spring or autumn day. For a rooftop system, a 5 kWh battery is usually the better match.
What to check first
First, the contract class. The residential progressive tariff has no time-of-use option, so this arithmetic does not apply to most mainland homes; Jeju and commercial or industrial premises do have it. Second, the basic fee. Time-of-use contracts charge on contracted demand, which can make them worse than the progressive tariff for low use. Third, cycle life: one cycle a day gives 6,000 cycles in 16 years, two cycles in eight.
Where the losses come from
Charging converts AC to DC and discharging converts it back, losing 2–4% each way, with further loss in the cells' internal resistance. The 90% round-trip figure combines all of it.
Charge rate matters too: fast charging loses more than slow charging. A home system that fills over ten off-peak hours is more efficient than one that fills in two. Setting efficiency to 85% in the calculator cuts revenue by more than 5%.
Seasonal operation
In summer the peak rate is high enough to justify two cycles; in spring and autumn the spread is too small, so one cycle protects the cells. In winter heating load raises peak-hour use, making each discharge more valuable.
Seasonal operation reduces annual cycles below 365 and extends life. Setting operating days to 300 in the calculator lowers revenue by about 20% but pushes replacement two to three years later, which is the conservative case.
A commercial example
A 20 kWh battery on a commercial building, run twice a day, earns about 3,600 KRW a day in summer and 830 in spring, or 400,000–700,000 a year. Against a 10m installation the payback is fifteen to twenty-five years.
Add demand-charge savings and the case changes. Cutting the maximum demand by 10 kW saves 740,000 a year, doubling the battery's return. A battery should be designed for peak shaving as well as arbitrage.
Rates are the industrial (Eul) high-voltage A option II values after the April 2026 reform and the June application date. Contract class and voltage change them, so check the bill first.
Questions
Can a home battery arbitrage on the mainland?
Mainland residential rates have no time-of-use option, so grid arbitrage is limited. Jeju homes and commercial contracts can; mainland homes earn by raising self-consumption instead.
Does 100% depth of discharge earn more?
It shortens life sharply. LFP cells are designed around 90%; repeated 100% cycles can cut cycle life by 20–30%.
Where does the 90% efficiency come from?
It combines battery round-trip efficiency with power-conversion losses. LFP home systems typically reach 88–93%, older lithium-ion 85%.
Use your own contract rates to price a cycle.
Open the calculatorBasis 2026-11-28. Written against primary tables; revised when a rate changes.
Back to the guides