Solar on an apartment versus a house

Basis 2026-11-28 · Flats and houses · about 6 min

The same array saves different amounts in an apartment and a detached house. Apartments often receive high-voltage power and split it between units, the roof is shared, and individual net metering may not be available. Each of those changes the arithmetic.

High voltage and low voltage

Residential high voltage charges 730, 1,260 and 6,060 KRW basic and 105.0, 174.0 and 242.3 KRW per kWh, 12–20% below low voltage. A 300 kWh high-voltage bill is 49,420 KRW against 57,760, so the rate a solar array displaces is lower and the saving is smaller.

When a whole block is on one high-voltage contract, usage may be averaged across units. Check with the management office and KEPCO how a unit's solar output is reflected. If each unit has its own meter and a low-voltage contract, the calculation matches a house.

ItemLow voltageHigh voltage
Basic, tier 1910 KRW730 KRW
Energy, tier 1120.0 KRW105.0 KRW
Energy, tier 3307.3 KRW242.3 KRW
300 kWh bill57,760 KRW49,420 KRW

Netting 3,900 kWh against 242.3 rather than 307.3 KRW cuts the saving by 15–20%. The array costs the same, so payback lengthens.

Shared roofs and balconies

An apartment roof is common property, so an individual cannot install at will. It needs the residents' committee and a change to the management rules; a whole-block array shares the revenue. A balcony system of 300–600 W is for self-consumption rather than net metering.

A 300 W balcony unit makes about 1 kWh a day, enough for a refrigerator, and saves 50,000–100,000 KRW a year. It is simple to install and can move with the tenant, which suits rented homes.

When an apartment still works

High daytime use, a bill in the third tier, or an electric car make solar worthwhile even in a flat. A whole-block array that reduces the management fee is the most efficient route, though it takes time to agree and needs a cost-sharing rule.

In the calculator, switch the contract class to high voltage to see the saving fall. For a balcony unit, enter 0.3–0.6 kW to get a realistic figure.

Management fees and common power

An apartment bill includes common electricity in the management fee: lifts, lighting and car-park ventilation. A whole-block array reduces that common charge, while a unit's own array only reduces the unit's bill, so the saving does not return through the fee.

Revenue sharing for a block array is set in the management rules: offset the common charge, distribute by area, or hold in reserve. The residents' committee must decide, and leaving it undefined invites disputes.

The limits of a balcony unit

A 300–600 W balcony system makes 1–2 kWh a day, enough for a refrigerator and lighting, not for air conditioning or a rice cooker. Net metering needs a KEPCO application, and plug-in units must include anti-islanding protection.

A balcony unit can be used in rented housing and taken along on a move, but the railing load, wind and the building rules all need checking. If the rules prohibit it, the management office will say so first.

Apartment examples

New apartment blocks increasingly include solar at the design stage to cut common electricity and earn green certification. Residents gain through the management fee, though the saving per unit is small.

Retrofitting an older block needs a structural survey and residents' consent, and roofs over twenty years old need waterproofing and reinforcement, which lowers the economics compared with a new build.

Numbers for a flat

High-voltage supply, 300 kWh of use, 3 kW and 40% daytime use saves about 15% less than the same house on low voltage, roughly 600,000 a year, so payback is more than a year longer. A 300 W balcony unit makes about 300 kWh and saves 50,000–80,000, with an eight-year payback on a 400,000–600,000 installation.

Contract class and netting arrangements differ by block. Confirm with the management office and the local KEPCO branch before calculating.

Questions

Is there a subsidy for balcony solar?

The housing programme covers detached and apartment buildings, but small balcony products are usually outside it or limited to local schemes.

Can I install on the shared roof myself?

No. It is common property and needs the residents' committee. A unilateral installation can be ordered removed.

Is solar worse on a high-voltage contract?

The saving is smaller because the avoided rate is lower, while the cost is the same. A smaller array or higher self-consumption compensates.

Compare the saving at high and low voltage.

Open the calculator

Basis 2026-11-28. Written against primary tables; revised when a rate changes.