Roof space and structure for 3 kW

Basis 2026-11-28 · Roof space · about 6 min

Three kilowatts needs seven or eight modules at 400–450 W each. A module is about 1.7 m by 1.1 m, or 1.9 m², so eight cover 15 m²; with walkways and clearance the roof area required is 18–22 m².

Modules and layout

Eight 400 W modules make 3.2 kW and seven 450 W modules 3.15 kW. Modules can be mounted portrait or landscape, and the roof width and slope decide the layout. Two rows on a south roof need roughly 4 m by 4.5 m.

ModuleCountModule areaRoof needed
400 W815.2 m²18–20 m²
450 W713.3 m²16–18 m²
500 W612.9 m²15–17 m²

A narrow roof can use higher-efficiency modules: six 500 W panels make 3 kW in 13 m². They cost more, so unless area is the constraint, 400 W is the economical choice.

Weight and structure

A module weighs 20–25 kg, so eight weigh 160–200 kg; with mounting and wiring the load is 250–300 kg, or 15–20 kg per square metre. That sits inside the design load of a residential roof, but an old slate roof or a heavy-snow area may need reinforcement.

There are two mounting methods: a frame that sits on the roof without penetrating it, and a fixed mount that penetrates the covering. The first leaves the waterproofing intact but is more vulnerable to wind; the second holds better but depends on proper sealing. Ask whether the installer provides a waterproofing warranty.

Clearance and shading

Walkways are needed for maintenance: at least 30 cm from the edge and 20 cm between rows. Chimneys and vents cast shadows, so keep a metre clear or leave those modules out. Shading one module can drag down a whole string unless optimisers are used.

Below 15 m², consider 2 kW rather than forcing 3 kW. Two kilowatts makes about 2,600 kWh a year, which suits a 250 kWh household. A cramped 3 kW loses output to shading and clearance and may perform like 2.5 kW. Compare both in the calculator before deciding.

Mounting by roof material

A tiled roof uses hooks over the battens, avoiding penetrations and reducing leak risk, but the hooks must resist wind uplift. A slate roof is often old, so check for asbestos and strength before loading it.

A metal roof uses clamps without drilling, though thin sheet can tear in wind, so thickness and clamp spacing matter. A flat roof is held by ballast or penetrates the slab, and the array must not block drainage.

Allow a margin

Add 20–30% to the module area for walkways and clearance: 15 m² of modules needs 18–20 m² of roof. Without a maintenance route, cleaning and inspection become difficult later.

Leave chimneys, vents and aerials clear. Shadow length changes with the sun's height, so keep a metre clear measured at winter noon. Raising the shading loss to 10% in the calculator shows the cost of getting this wrong.

Outbuildings

A narrow main roof can be supplemented by a shed or garage roof, but the array must be at the same metered site for net metering, and a different plot needs a separate contract. Shed roofs are often weak and need reinforcement.

A carport or garden structure adds area at the cost of wind, appearance and boundary questions. Splitting 3 kW across two structures costs more than concentrating it in one place.

When the roof is too small

Below 15 m², use higher-efficiency modules or size down to 2 kW. Two kilowatts makes about 2,600 kWh and suits a 250 kWh household, with a smaller subsidy and own contribution. A shed or carport can add area only if it shares the metered site; otherwise a separate contract and cabling are needed.

Areas and weights are for typical 400–500 W modules. A structural engineer should confirm the roof material, slope, snow load and wind load.

Questions

How many square metres is 3 kW?

15–22 m², about 5–7 pyeong. Allow 7 pyeong for walkways and clearance.

Can I install on a balcony or flat roof?

Yes, subject to structural load, waterproofing and grid connection. Balcony systems in apartment blocks need a separate product and residents' consent.

Does a non-south roof need more space?

A lower yield means more capacity for the same output, so yes: replacing a 17% orientation loss needs about 3.6 kW.

Match the array size to your roof area.

Open the calculator

Basis 2026-11-28. Written against primary tables; revised when a rate changes.