Battery life and the replacement year
Battery life is measured two ways: cycle life, the number of charge and discharge cycles, and calendar ageing, the loss that happens even when the battery sits idle. A home system is replaced when either limit arrives first.
Cycle life
LFP cells are quoted at 3,000–6,000 cycles and NMC at 1,500–3,000. At one cycle a day, 6,000 LFP cycles last 16.4 years and 2,500 NMC cycles 6.8 years. At two cycles a day even the LFP falls to 8.2 years.
| Battery | Cycle life | One a day | Two a day |
|---|---|---|---|
| LFP | 6,000 | 16.4 years | 8.2 years |
| LFP, conservative | 4,000 | 11.0 years | 5.5 years |
| NMC | 2,500 | 6.8 years | 3.4 years |
The table assumes 365 operating days. Real use varies with the season, and summer heat accelerates ageing. A conservative 4,000 cycles brings LFP replacement forward to eleven years.
Depth of discharge and temperature
Limiting depth of discharge to 90% extends life; repeated 100% cycles shorten it. That is why manufacturers recommend 90%. Temperature matters more: a battery at 25°C and one at 35°C can differ by more than 30% in life, so an indoor or insulated location is worth more than a cheaper outdoor cabinet.
LFP charging is restricted below freezing; the management system slows or stops it. An indoor site is better for both life and winter performance, so check ventilation and temperature when choosing where the unit goes.
The economics of replacement
A replacement costs 60–70% of the original installation, roughly 3–3.5m KRW for 10 kWh. Over twenty years one replacement is likely at year sixteen, and leaving it out overstates NPV.
At replacement, decide whether to keep the size. A larger battery with an unchanged array has less surplus to fill; a new EV or heat pump may justify more capacity. Change the replacement year and cost in the calculator to test both.
Calendar ageing
A battery loses capacity with time even when idle: 2–3% a year for lithium-ion and 1–2% for LFP. Over ten years LFP loses 10–20%, so a 16-year cycle life can still end in replacement at twelve to fourteen years.
Holding a full charge accelerates calendar ageing, which is why manufacturers recommend 90%. For a long absence, 50–60% is better. That kind of management adds two or three years.
Safety and disposal
Batteries carry fire risk, so location, ventilation and isolation matter. Indoors, check fire compartmentation and smoke detection, and use the manufacturer's approved installer. Granted systems may carry disposal conditions.
End-of-life units are recycled or disposed of through a scheme that is still maturing in Korea, and disposal can cost money. A conservative twenty-year cash flow includes it.
Reuse and recycling
A retired home battery with 70% capacity can serve a charging station or a small storage duty; backup and peak shaving do not need full capacity. The Korean reuse market is small but can beat disposal.
Recycling recovers lithium, nickel and cobalt through specialist firms, and some manufacturers run take-back schemes. Checking the disposal route at installation avoids a surprise later.
Operating for life
Keep the state of charge near 90%, leave 10% in the cells and avoid repeated fast cycling. Keep the unit below 30°C in summer and choose a model with pre-heating if it sits in an unheated space; LFP charging is limited below freezing.
Charging to 100% and discharging to zero every day can halve life; running between 20% and 90% can extend it by more than half, and slow overnight charging is gentler than repeated fast charging.
Cycle life is a warranty figure; real life depends on temperature, depth of discharge and charge rate. Replacement cost is a typical 2026 Korean quote for LFP.
Questions
How often is a battery replaced?
LFP lasts 10–16 years at one cycle a day, NMC 7–10. Heat and deep cycling shorten both.
How do I know capacity has fallen?
Monitoring shows charge and discharge falling more than 20% below the original. Some battery managers report state of health directly.
Is it unsafe to keep using an old battery?
Capacity falls and internal resistance rises, which increases heat risk. Replacing at the manufacturer's recommended point is safer.
Price the twenty-year cost with your cycle life.
Open the calculatorBasis 2026-11-28. Written against primary tables; revised when a rate changes.
Back to the guides