Counting the carbon a system avoids
Solar and heat pumps cut carbon in different ways, and both are counted by multiplying activity by an emission factor. The hard part is not the arithmetic but choosing the baseline: what would have happened without the system.
The factors
Grid electricity uses the 2023 consumption-side national factor of 0.4173 t CO2e per MWh, or 0.4173 kg per kWh, published in December 2025; the update cycle has shortened from three years to one. City gas is 2.16 kg per Nm³ and kerosene 2.46 kg per litre, both combustion-only and excluding extraction and transport.
| Fuel | Unit | Factor | Note |
|---|---|---|---|
| Electricity | kWh | 0.4173 kg | 2023 consumption side |
| City gas | Nm³ | 2.16 kg | LNG |
| Kerosene | L | 2.46 kg | Indoor kerosene |
A 3 kW array making 3,900 kWh avoids 3,900 × 0.4173 = 1,627 kg, about 1.63 t a year, on the assumption that the household would otherwise have bought that power and that the grid mix is unchanged.
The heat pump's saving
A heat pump is not zero-emission; it uses electricity. Twelve thousand kWh of heat at COP 3.2 needs 3,750 kWh, emitting 1,565 kg. A gas boiler burns 46,957 MJ, or 1,099.7 Nm³, emitting 2,375 kg. The difference is 810 kg, 0.81 t.
Against kerosene the gap widens: 1,388 litres emit 3,416 kg, so the heat pump avoids 1,851 kg, 1.85 t. That is why replacing kerosene in a rural house is the strongest carbon case in the programme.
Choosing the baseline
The solar figure depends on the grid it displaces. As the grid decarbonises, the same array avoids less: at a 2030 factor of 0.35 the 3,900 kWh saves 1.37 t. A solar carbon claim therefore weakens over time.
The heat pump moves the other way. A cleaner grid makes each kilowatt-hour move more heat for less carbon, and pairing the heat pump with solar makes its electricity nearly carbon-free, roughly doubling the saving. The two technologies reinforce each other.
Direct and indirect
Solar has no direct emissions, so its saving is counted as avoided indirect emissions from grid power. A heat pump has indirect emissions from its electricity, while a gas or kerosene boiler has direct emissions from combustion. A comparison should state which scope it counts.
Corporate inventories split Scope 1 (direct) and Scope 2 (purchased electricity). Solar reduces Scope 2; a heat pump reduces Scope 1 and increases Scope 2. Household arithmetic can ignore the split, but a report cannot.
Life-cycle emissions
Modules emit carbon in manufacture, transport and disposal: 600–800 kg per kW, or about 2 t for 3 kW. At 1.6 t avoided a year, that is repaid in one to two years. A heat pump also carries manufacturing emissions, though the use-phase saving is larger.
This calculator counts the use phase only. Including the life cycle reduces the first-year figure but leaves a net reduction over twenty years. For formal accounting, use a life-cycle assessment.
A household example
A household buying 4,200 kWh that installs 3,900 kWh of solar cuts grid use to 300 kWh, and emissions from 1.75 t to 0.13 t, a 1.62 t reduction. Adding a heat pump cuts gas from 2.38 t to 1.56 t, taking the total above 2.4 t.
That is roughly what a hundred trees absorb in a year, and 48 t over twenty years. It is one of the surest ways for a household to cut its footprint.
What reduces the saving
The solar figure depends on the grid factor. At 0.4173 in 2023 falling to 0.35 by 2030, the same 3,900 kWh moves from 1.63 t to 1.37 t. A heat pump moves the opposite way, because a cleaner grid makes each kilowatt-hour carry more heat, so the two together produce the largest reduction.
Factors come from the national greenhouse gas platform. Voluntary credits or recognised reductions need a separate methodology and verification.
Questions
How much does 1 kW avoid?
At 1,300 kWh a year it avoids 0.54 t; at 1,430 kWh, 0.60 t. A 3 kW array lands at 1.6–1.8 t depending on region and orientation.
Is a heat pump always lower carbon than gas?
At the 2026 factor of 0.4173, yes. In a coal-heavy grid with a low COP the gap narrows.
Can I sell the reduction?
Residential systems are outside the REC and offset markets. Corporate RE100 and inventories have separate recognition rules.
Count your system's annual reduction.
Open the calculatorBasis 2026-11-28. Written against primary tables; revised when a rate changes.
Back to the guides