Degradation at 0.5% and the year-12 inverter
A solar array produces most in its first year and then declines. Module warranties typically assume 0.5% a year, which leaves 90.5% after twenty years. A 3 kW array that made 3,900 kWh in year one makes about 3,530 in year twenty.
What degradation does to the saving
Output falls while the tariff rises. At 3% a year the price index reaches 1.75 by year twenty. Output at 90.5% times a price at 1.75 leaves a saving about 1.58 times the first year. Degradation alone looks like a loss, but the tariff more than covers it.
The calculator recomputes each year with the degradation on output and the escalation on the tariff. Multiplying the first-year saving by twenty differs by more than 10% from the modelled total, so a simple multiplication misstates the payback in either direction.
| Year | Output (3 kW) | Price index | Saving index |
|---|---|---|---|
| 1 | 3,900 kWh | 1.00 | 1.00 |
| 5 | 3,803 kWh | 1.13 | 1.10 |
| 10 | 3,717 kWh | 1.30 | 1.24 |
| 15 | 3,632 kWh | 1.56 | 1.45 |
| 20 | 3,530 kWh | 1.75 | 1.58 |
The inverter is a decade-scale cost
Modules last 25 years; inverters do not. Warranties run 5 to 12 years and replacement at 10–12 years is common. A 3 kW inverter costs 1.0–1.5m KRW to replace. Leaving it out of the twenty-year cash flow overstates NPV by 300,000–1,000,000 KRW depending on the discount rate.
It also lengthens the payback. A system saving 600,000 KRW a year that spends 1.5m in year twelve reaches 4.2m of cumulative cash rather than 5.7m, pushing simple payback out by one to two years. Enter the real replacement year and cost.
Where the inverter sits matters. Direct sun, a closed cabinet and a hot summer shorten its life; shade and ventilation extend it. Some units last fifteen years in a good position. Checking the mounting location before signing is cheaper than replacing early.
How to read a degradation figure
0.5% is a warranty number. Measured output often drops 1–2% in the first year and then flattens. To reflect that, treat the first year as 97% of the model output by adding the initial loss to the shading and soiling input. The long-run rate then behaves as the warranty says.
Running the calculator at 0.4% and 0.7% changes the twenty-year total by 3–4%. That is small, but when comparing modules with different warranties it is the number to weigh against the price difference.
Reading the warranty
Module warranties split into product and performance. The product warranty replaces defects; the performance warranty replaces a module that falls below a set output. Performance terms usually allow 2–3% in year one and 0.5% a year after. Both numbers should appear in the document.
Inverter warranties split into product and installation. A ten-year product warranty does not cover damage from a poor installation. Extended warranties are sometimes sold separately, and the twenty-year cash flow should say whether one is included.
Signs that replacement is near
Falling conversion efficiency shows as lower output at noon on a similar day. A 5% drop year on year, a louder fan, an error code or frequent restarts all point to a service visit. Monitoring that records daily output makes the comparison possible.
A hybrid inverter running a battery works harder and may fail sooner. Its replacement costs more than 2m KRW, so the twenty-year table should carry that figure rather than the plain inverter cost.
The choice at year twenty
After twenty years the modules still produce about 90%, while the inverter may be due for a second replacement. Replacing it with a hybrid and adding a battery renews the system for about 3m KRW.
Replacing the whole array can be better: module prices have fallen, so turning a 3 kW system into 4 kW may beat a new inverter alone. Compare the twenty-year NPV of both.
Degradation refers to module output; system efficiency also depends on inverter efficiency and wiring. Replacement cost is a typical 2026 Korean quote for a 3 kW unit.
Questions
Does generation stop after twenty years?
No. Year twenty still produces 90.5% of year one, and year twenty-five about 88%. The warranty ending is not the end of life.
Must the inverter be replaced?
Failures rise between ten and twelve years, and replacing before failure avoids repair costs. One replacement in twenty years is the realistic assumption.
Is a lower-degradation module worth a higher price?
The difference between 0.4% and 0.5% is about 2% over twenty years. If the price gap is larger, weigh the warranty length, low-carbon certification and service instead.
Change the degradation and replacement year to compare NPV.
Open the calculatorBasis 2026-11-28. Written against primary tables; revised when a rate changes.