Inverter replacement: when and how much

Basis 2026-11-28 · Inverter · about 6 min

The first part of a solar system to fail is rarely the module. It is the inverter, where power electronics, fans and capacitors wear under heat. Module warranties run to 25 years; inverter warranties run from 5 to 12, and replacement at 10–12 years is routine.

What it costs

A 3 kW inverter costs 1.0–1.5m KRW to replace: about 700,000–1m for the unit plus installation, wiring and a grid-connection check. A 5 kW unit runs 1.5–2.5m and a 10 kW unit 2.5–4m. New monitoring hardware and breakers add more.

SizeUnitReplacement totalTypical life
3 kW0.7–1.0m1.0–1.5m10–12 years
5 kW1.0–1.8m1.5–2.5m10–12 years
10 kW1.8–3.0m2.5–4.0m10–15 years

Leaving the replacement out of a twenty-year cash flow overstates NPV. A system saving 600,000 a year that spends 1.5m in year twelve reaches 10.5m rather than 12m, and at a 4.5% discount the year-twelve spend costs about 880,000 in today's money.

Making it last longer

Location decides much of the life. Direct sun, a sealed cabinet and a 40°C summer shorten it; shade, ventilation, a 30 cm gap from the wall and a dust-free mounting extend it. Some units in good positions reach fifteen years.

Watch for the early signs: a louder fan, output dropping in the monitoring app, an error code on the display. A fault left alone accumulates lost generation and, in some topologies, exposes modules to reverse current.

What to change at replacement

Replacement is the moment to consider a larger or hybrid inverter. If you plan more modules or a battery, a hybrid unit saves a second conversion. The grid connection limit and KEPCO approval still have to be checked.

Check the warranty of the replacement. A five-year warranty means a second replacement inside twenty years; a ten-year unit costs more but can push the second replacement beyond year twenty. Running the calculator at ten and twelve years shows the NPV difference.

Inverter types

A string inverter converts several modules wired in series, which is cheap and simple but loses output when one module is shaded. Micro-inverters convert each module separately, resisting shading but costing more and requiring per-module replacement.

A hybrid inverter also manages battery charging. If a battery is planned later, choosing hybrid at the start avoids a second converter. Adding a battery to a plain inverter needs extra hardware and costs more.

Scope of the work

Replacement covers more than the box: wiring checks, breaker condition, earthing, the communication module and a grid-connection check. A ten-year-old unit may use different module connectors, requiring adapters.

A change of capacity or a switch to hybrid may need a KEPCO connection amendment. Make the installer responsible for that in writing, so the paperwork does not land on the owner.

The value of an extension

Extending an inverter warranty from ten to fifteen years costs 300,000–500,000, which is cheap insurance against a 1.5m replacement. Extensions are only available from some manufacturers.

Out of warranty, a repair costs 300,000–800,000, and on a unit over ten years old replacement is usually better because parts may be discontinued. Bringing the replacement forward to year ten is a valid choice.

When it fails

Switch off the breaker, record the error code and call the manufacturer with the purchase date to confirm the warranty. Generation stops while the unit is down, which costs more than 10 kWh a day in summer. Never connect a temporary inverter yourself: grid rules, shock risk and warranty exclusion all apply.

Installation position also decides how soon the next one comes: a shaded, ventilated wall can reach fifteen years, while a unit in direct sun can fail at eight.

Costs are typical 2026 Korean quotes for a 3 kW unit. Brand and hybrid capability change them.

Questions

Does generation stop when the inverter fails?

Yes. Without conversion from DC to AC the modules can produce but the house cannot use the power, so generation is lost for the outage.

Is a warranty repair free?

The manufacturer usually covers the unit, while installation and call-out may be charged. Write the terms into the contract.

Does a bigger inverter increase output?

Barely, if the array is unchanged. Size it at 80–110% of module output; oversizing hurts low-load efficiency.

Change the replacement year and compare twenty-year NPV.

Open the calculator