Basis 2026-11-28 · Regional yield · about 6 min

Quotes often quote one number for the whole country: about 1,300 kWh per kWp a year. The modelled values spread from 1,283 to 1,480. At 3 kW that is 3,849 against 4,440 kWh, a gap of nearly 600 kWh and more than 150,000 KRW a year.

The model values

PVGIS from the European Commission's Joint Research Centre combines satellite irradiance, temperature and system losses into hourly output. The annual values below assume due south, optimum tilt and 14% system loss. They are model estimates, not measurements, so read them with a ±10% band.

CitykWh/kWp3 kW yearMonthly average
Seoul1,4304,290358
Incheon1,4454,335361
Suwon1,4304,290358
Daejeon1,4154,245354
Gwangju1,3944,182349
Daegu1,4304,290358
Busan1,4774,431369
Ulsan1,4804,440370
Changwon1,4754,425369
Jeju1,3273,981332
Seogwipo1,2833,849321

The southern coast beats Seoul, because it sees more annual irradiance and fewer summer clouds. Jeju and Seogwipo sit lower despite decent sun, because wind, humidity and frequent cloud are built into the model. On Jeju, wind loading and salt protection also add installation cost.

When the monthly shape matters more

Two regions with the same annual yield can still produce different savings. A region with a strong May peak accumulates credit, while one with steadier winter output self-consumes better against heating load. The calculator applies the national monthly shape and changes only the annual yield.

The shape runs from 5.6% in January to 11.2% in May. December output is about half of May. For a household adding a heat pump, that is the difficult fact: heating demand peaks when output is lowest.

How far to trust a regional number

PVGIS assumes an average roof. The same district can vary by 20% with a hill, a tree or a neighbouring building. Ask the installer for a shading study, and if possible ask a neighbour with a year of operation what their inverter reports.

In the calculator, changing the region updates the annual yield and the monthly table at once. If you are comparing two locations, calculate both and look at the difference. When it exceeds 10% of the installed cost, location is the decisive variable.

Irradiance and temperature together

Output is not set by irradiance alone. Module power falls as temperature rises: at 35°C air temperature the cells can reach 60°C and lose more than 10% of output. A sunny southern region can therefore produce less at midsummer than in spring.

PVGIS includes temperature and wind in its model. A mounting that allows air to flow behind the modules runs 5°C cooler, which can matter as much as a regional difference. A well-ventilated roof can close half the gap between two cities.

Choosing a regional value

Pick the city closest to the site; the spread between cities is within 10%, so a district value is not essential. Coastal, inland, mountain and plain sites can differ more than the city average, however, so adjust the loss input rather than the yield.

For an outlying site, adding 5% to the shading and soiling loss is the safe choice. On a clear southern coast, 2% less is reasonable. Either way, the survey on the day of installation is worth more than the regional number.

When a neighbour's data disagrees

If a neighbour's identical system reports 3,500 kWh against a model of 4,290, the 800 kWh gap is usually shading, soiling and inverter efficiency. Treat the model as an upper bound and plan on a figure 15% lower.

Recording the first year's output lets you recalibrate the saving from year two. Adjusting the shading loss in the calculator to match reality makes the twenty-year view more accurate.

Annual yields are PVGIS values; the monthly distribution is the national normalised shape. Actual output depends on orientation, tilt, shading and module soiling.

Questions

Does Seoul really beat Jeju?

In the model, Seoul is 1,430 and Jeju 1,327 kWh per kWp. Jeju has good sun but wind, humidity, cloud and salt reduce the modelled output.

Is the south always better?

Busan, Ulsan and Changwon score high, but siting and shading can reverse a regional difference. Within one city the spread reaches 20%.

How far off is the model from reality?

PVGIS assumes ±10%. Soiling, inverter efficiency and wiring can take another 5–15%, so enter a shading and soiling loss of at least 5%.