Winter yield and heating electrification
Solar seems like a summer technology, but in Korea May is the peak month: clear skies before the rains and moderate module temperatures. December and January fall to about half of May because days are short and cloud and snow are frequent.
The month-by-month gap
A 3 kW array in Seoul makes 431 kWh in May and 215 in December. July and August sit at 285–300 because of the monsoon and heat. A household that uses more in summer sees output and demand out of phase, which produces surplus credit in some months and a shortfall in others.
| Month | 3 kW output | 350 kWh household | Difference |
|---|---|---|---|
| January | 215 kWh | 350 kWh | −135 |
| April | 400 kWh | 350 kWh | +50 |
| May | 431 kWh | 350 kWh | +81 |
| July | 285 kWh | 420 kWh | −135 |
| October | 369 kWh | 350 kWh | +19 |
| December | 215 kWh | 350 kWh | −135 |
The household column assumes even use. With electric heating, December and January rise to 600 kWh while output stays at 215, so the gap widens to 385 kWh. Credit covers some of it; the rest is bought.
With a heat pump
Adding a heat pump raises winter use exactly when output is lowest. The combination produces surplus in summer and a deficit in winter, and no home battery can bridge seasons. Buying winter power from the grid is the realistic design.
The important lever is the winter price. On the progressive tariff, winter use enters the third tier at 307.3 KRW and the super-user rate at 736.2. The dedicated heat-pump tariff introduced in April 2026 keeps the effective price near 130 KRW, which is what makes the combination work.
Getting more from winter
A 45° tilt faces the low winter sun and sheds snow, at a small cost in summer output. Brush snow off carefully; high-pressure water and hot water damage modules. Ground reflection from snow can add a little output, but snow load on the mounting is a structural question.
Set December use to 600 kWh in the calculator and watch the winter bill. That is the number a heat pump has to beat against gas, and it is far above the annual average.
Snow and clearing
Five centimetres of snow can take output to near zero. Waiting for a thaw is safest, but a long cover loads the structure. Climbing onto the roof is dangerous, so clear only what a long brush reaches from the ground.
A 45° tilt sheds snow naturally, though melt refreezing can form icicles under the modules. Where the array overhangs a walkway, a guard is worth installing.
Cold-weather efficiency
Modules run more efficiently when cold: at minus 5°C air temperature the cells may sit near 10°C and produce 5–8% more than at 60°C in summer. A clear cold winter day can therefore beat a summer day in efficiency. The problem is the short day.
The low winter sun casts long shadows, so a tree or building that is harmless in summer can shade the array in December. Check the winter-noon shadow before installing, not after.
The winter bill
A household using 600 kWh in December pays about 219,000 KRW on low voltage. A 3 kW array making 215 kWh self-consumes 140 and nets 75, saving about 30,000. With a heat pump the use rises and the saving grows, but at the third-tier rate.
Watch the super-user limit: above 1,000 kWh the excess costs 736.2 KRW and the bill jumps. A household running a heat pump and electric mats can cross 1,000 kWh in December without noticing.
Monthly shares are the national normalised distribution. A snowy or cloudy winter can push December lower still.
Questions
Does solar stop in winter?
No. A 3 kW array still makes 215 kWh in December, half of May but far from zero, and enough for daytime self-consumption.
Should snow be cleared?
Yes, snow blocks output, but roof access is dangerous. Clear only what a long brush reaches from the ground.
How much does a heat pump raise the winter bill?
Twelve thousand kWh of heat at COP 3.2 needs 3,750 kWh of power, about 940 kWh a month, which reaches the third tier and super-user rate on the progressive tariff.
Set a winter use figure and see the December bill.
Open the calculatorBasis 2026-11-28. Written against primary tables; revised when a rate changes.
Back to the guides